fixed issues in sigmoid sensor model causing inverted response (annular partitions)

This commit is contained in:
2025-11-24 17:39:16 -08:00
parent 66bbfe52ca
commit f7b28cdf4f
55 changed files with 44 additions and 31 deletions

View File

@@ -13,8 +13,8 @@ classdef test_sigmoidSensor < matlab.unittest.TestCase
betaTiltMax = 15;
alphaDistMin = 2.5;
alphaDistMax = 3;
alphaTiltMin = deg2rad(15);
alphaTiltMax = deg2rad(30);
alphaTiltMin = 15; % degrees
alphaTiltMax = 30; % degrees
end
methods (TestMethodSetup)
@@ -31,7 +31,7 @@ classdef test_sigmoidSensor < matlab.unittest.TestCase
tc.testClass = sigmoidSensor;
alphaDist = 2.5;
betaDist = 3;
alphaTilt = deg2rad(15);
alphaTilt = 15; % degrees
betaTilt = 3;
tc.testClass = tc.testClass.initialize(alphaDist, betaDist, NaN, NaN, alphaTilt, betaTilt);